Technical Data
Downloads To login
Circuit diagram [Circuit diagram HE 302]
Supply +24 V DC
Servovalve output 0 … ± 650 mA
Analogue inputs (4x) 0 … 5 V, 0 … 10 V
± 5 V, ± 10 V
Position transducer non-contact LVDT amplifer for inductive motion pickup on board
Digital inputs (6x) 0 / 24 V with LED
Digital outputs (6x) 0 / 24 V mit LED
Parameter intersection CNC-Bus 16 bit parallel, RS 232
Dimensions (BxHxT) 105/150 mm x 110 mm x 185 mm
[PID-controller HE 303]

Digital universal PID controller HE 303

Universal digital controller.

Can be parameterized via RS 232 interface and Windows® terminal program. Interactive configuration menu in controller, no additional software or devices necessary.

Analog input/output with 12-bit resolution. Controller scan time 1 ms. Two control loops per circuit board possible, with additional valve current amplifier.

Technical Data
Downloads To login
Circuit diagram [Circuit diagram HE 303 / HE 304]
Supply +24 V DC
Output current 0 … ± 200/300/660/1000 mA
Analogue inputs (4x) 0 … 5/10 V, ± 5/10 V, 0/4 … 20 mA
Digital inputs (4x) 0 / 24 V
Interface of motion pickup SSI or SST or CAN-Bus transducers
Analogue outputs (2x) 0 … ± 10 V
Digital outputs (4x) 0 / 24 V 100 mA
Parameter intersection RS 232 / 422
Interface CAN-Bus (Profi-, Interbus optional)
Protection rating IP 65
Connections Sensor plug M12
Dimensions (Box) 100 mm x 160 mm x 82 mm
[PID-controller HE 304]

Digital, universal controller HE 304

Universal digital controller.

Can be parametered by interface with Windows terminal program. Interactive configuration with the controller, no additional software or devices necessary.

Analogue input / output with 12bit resolution. Scan time of the controller 1 msec. Two control loops in one controller are possible.

Technical Data
Downloads To login
Circuit diagram [Circuit diagram HE 303 / HE 304]
Supply +24 V DC
Output current 0 … ± 200/300/660/1000 mA
Analogue inputs (4x) 0 … 5/10 V, ± 5/10 V, 0/4 … 20 mA
Digital inputs (4x) 0 / 24 V
Interface of motion pickup SSI or SST or CAN-Bus transducers
Analogue outputs (2x) 0 … ± 10 V
Digital outputs (4x) 0 / 24 V 100 mA
Parameter intersection RS 232 / 422
Interface CAN- / Profi-Bus
Dimensions 100 mm x 160 mm, 10 TE