Schneider Kreuznach Servo Hydraulics

Jump to Content, Main Navigation, Local Navigation.

Mounting Pattern NG 6

[Mounting pattern NG 6]

The servovalve range embraces single, two and three-stage valves in a flow rate range from 0.4 to 1000 l/min. Besides the standard range, application-related valve series are available, e.g.:

  • special characteristics,
  • low-leakage pistons,
  • two return flanges or
  • highly dynamic valves
Comparison Chart HVM 061 / HVM 062
[Servovalve HVM 061 / HVM 062]

HVM 061

HVM 062

Single-stage servovalve with or without electronics Two-stage servovalve with or without electronics
[Circuit diagram HVM 061 / HVM 063] [Circuit diagram HVM 062 / HVM 064]
Download To login To login
Rated flow 0,4 - 8 l/min 5 - 30 l/min
Operating pressure 0 - 315 bar 5 - 315 bar
Rated current ± 200 mA ± 200 mA
Step response 0 - 90% 3,5 ms 3 ms
Resolution without dither < 0,2 % < 0,2 %
with integrated electronics
Supply 24 VDC 24 VDC
Nominal value (optional) ± 10 V
0-20 mA
4-20 mA
± 10 V
0-20 mA
4-20 mA
Comparison Chart HVM 063 / HVM 064
[Servovalve HVM 063 / HVM 064]

HVM 063

HVM 064

Single-stage servovalve with or without electronics Two-stage servovalve with or without electronics
[Circuit diagram HVM 061 / HVM 063] [Circuit diagram HVM 062 / HVM 064]
Download To login To login
Rated flow 0,5 - 20 l/min 5 - 40 l/min
Operating pressure 0 - 315 bar 5 - 315 bar
Rated current ± 300 mA ± 300 mA
Step response 0 - 90% 5 ms 4 ms
Resolution without dither < 0,2 % < 0,2 %
with integrated electronics
Supply 24 VDC 24 VDC
Nominal value (optional) ± 10 V
0-20 mA
4-20 mA
± 10 V
0-20 mA
4-20 mA

Back to top


Modified: 2010/09/02. Page generated in 0.0440 seconds.